Milwaukee MC122 PRO pH Controller
Code: MC122Related products
Product detailed description
Milwaukee MC122 PRO pH Controller automatically monitors pH and activates a switched socket for pumps or CO2 dosers. Set the required pH values and let the controller manage the readings and socket operation. It suits large nutrient solution tanks and aquariums.
Control and monitoring
- Two-point manual calibration provides accuracy of up to +/- 0.2 pH.
- The control range is 5.5 to 9.5 pH, with an alarm that activates when the reading rises above or falls below the set value.
- The large LC digital display makes current readings quick and easy to check.
- High and low set values can be adjusted to match the required range.
- Manual trimmers make two-point calibration straightforward and help maintain accuracy.
Probe and connection
- The gel-filled, laboratory-grade pH electrode requires little maintenance and provides high power.
- The 2 m probe cable gives you greater flexibility during testing.
- The complete mounting set includes a probe holder.
- The included MA911B/2 pH electrode and 12 V DC adapter are supplied with the controller.
Probe construction and lifespan
pH metres commonly develop problems at the probe. The glass sensing bulb gradually loses sensitivity through use and eventually fails; this applies to all pH probes. The reference junction is a small opening that allows the metre to compare the sample with reference values. The reading is based on the electrical difference between them, so a blocked junction stops the probe from working.
Storage
- Keep the pH probe hydrated. Long periods in dry storage reduce its sensitivity and can block the reference junction.
- Store the probe in pH probe storage solution or pH calibration buffer to help prevent these problems.
- Do not store the probe in tap water or distilled water, as either will damage its sensitivity.
- For storage, fill the protective cap with storage solution or calibration buffer and tighten it to prevent leaks.
- Store the electrode upright to further reduce the risk of leakage.
Cleaning and calibration
- Residue from nutrient solution can reduce probe sensitivity and block the reference junction, particularly when the sample contains a lot of organic material.
- Soak the electrode regularly in cleaning solution.
- pH probes become less sensitive over time, so calibrate the controller regularly to maintain accuracy.
- Calibrate the probe after cleaning or extended storage.
Specifications
- Measuring range: 0.0 to 14.0 pH
- Resolution: 0.1 pH
- Accuracy: +/- 0.2 pH
- Set value: 5.5 to 9.5 pH
- Calibration: manual two-point
- Alarm: active when the reading is higher or lower than the set value
- Dosing contact: 1 power socket for CO2 dosing
- Operating environment: 0 to 50 °C / 32 to 122 °F
- Maximum relative humidity: 95%
- Power supply: 12 V DC adapter
- Power supply: 115 V AC, 2 A, 60 Hz or 230 V AC, 1 A, 50 Hz
- Mounting set: included
- Dimensions: 5.9 x 3.2 x 1.35 inches
Additional parameters
| Category: | pH metres |
|---|---|
| Weight: | 0.18 kg |
| PFHGX: | Cheap, Best-selling, Recommended, High-quality, Branded, Basic |
Discussion